MULTIPLE SINK APPLICATION
MODEL
E-90FLL-220
Technical Data Sheet
|
| |
|
| |
ACCESSORIES
PROVIDED:
Compression
fittings and OMNI Faucet Flow Control 0.5 GPM
|
PRODUCT
LISTINGS:
UL, HUD, IAPMO,
UPC
|
MISCELLANEOUS:
 |
Factory
Pre-set Output Temperature
 |
0.5 GPM
Flow Rate
 |
0.5 GPM
Activation Point
 |
45 PSI
Minimum Required
|
| | |
|
| |
|
| |
SUGGESTED
SPECIFICATIONS:
The
water heater shall be a Chronomite Laboratories Instant-Temp
Microprocessor Temperature Controlled Tankless Electric Heater, Flow
Activated, Model Number ______________, with Celcon Waterways and
Stainless Steel Heating Coils, or an approved equal. Hot Water Storage
Vessels are expressly Prohibited.

|
MODEL
NUMBER SELECTION:
(Example)
|
|
E-90 |
FLL |
220-VAC |
| Model
# |
|
Voltage |
| VOLTAGE |
WATTS |
AMPS |
WIRE
SIZE |
TEMP
RISE
0.5 GPM |
TEMP
RISE
1.0 GPM |
TEMP
RISE
1.5 GPM |
| 220 |
9000 |
40 |
8
AWG |
122° |
61° |
41° |
Preset
output temperature at _______°F
|
|